Collect at least 2 mL of blood into a 4 mL vacutainer at the clinical site and invert 10x.
Transfer 2 mL of blood to Buffer 1; incubate at room temp for 15 mins.
Transfer 4.8 mL of sample to Buffer 2; store at -80°C or ship on dry ice.
Yes, Teiko integrates complete blood counts from your central lab with cytometry data from TokuKit-fixed samples to calculate absolute cell counts.
One sample is preserved with TokuKit for cytometry, while the other is kept fresh for hemoanalysis.
The fresh sample is sent to your central lab for hemoanalysis to measure leukocytes per µL, while the TokuKit-fixed sample is sent to our lab for cytometry.
Our computational pipeline derives absolute cell counts by multiplying population frequencies with the leukocytes per µL value, then displays the results on the dashboard.